Output Frequency : 50hz,60hz
Model Number : GWV-600
Weight : 1.88
Type : DC/AC Inverters
Output Current : 50A
Output Power : 401 - 500w
Size : 31x21x12
Output Type : Single
is_customized : Yes
Input Voltage : 22-60VDC
Output Voltage : 110V,220V
Output Power : 600W
Cooling : Fan
Features of Smart Microinverter:
1. Unique circuit design, choice of import industrial electronic components, higher efficiency, more stable performance.
2. Creative MPPT technology, efficiency more than 99%, faster and more sensitive reaction, more reliable.
3. Parallel type design for DC input and modularization design for inverter, small volume, distributed installation, easy for system configuration, flexible for combination, strong expansibility of system.
4. Adopting high-frequency isolation transformer type, high efficiency, and high security.
5. Perfect electrical protection function.
6. Aluminum alloy housing, not rust, heat-resisting and cold-resistant as well as anti-corrosion.
7. Getting electronic circuit design, appearance design and other core technology patents.
8. Wide input voltage (15-60VDC), classification processing for different input voltages. It can work with different DC power supplies.
Technical Parameters:
Rated Power: 600W
Solar Panels: ≥600W
DC Input Range: 22-60VDC
MPPT Voltage: 18-48V
DC MAX. Current :50A
AC Output Range :120VAC(90-140VAC) or 230VAC(190-260VAC)
Frequency Range :50Hz/60Hz(Auto control)
Power Factor: >97.5%
THD: <5%
Phase Shift: <2%
Efficiency :120VAC(90-140VAC)
Peak Efficiency:>85%
Stable Efficiency: >83%
Efficiency 230VAC(190-260VAC)
Peak Efficiency:>85%
Stable Efficiency: >84%
Protection:
Islanding; Short-circuit; Converse Connection; Low
Voltage; Over Voltage; Over Temperature Protection
Work Temperature -25°C-65 °C
Work Humidity 0%~90%RH non-condensing
Grade of
Waterproof
Indoor Design
Show Luminous Diode (LED)
Cooling Fan
Stand-by Power<2W
EMC EN61000-6-3:2007 EN61000-6-1:2007
Grid Disturbance EN 50178+EN 62109-1+VDE0126-1-12
Grid Detection DIN VDE 1026 UL1741
Certificate CE
Mounting dimension 16 x 13CM
1. Red LED
1.1 Red FAULT LED indicator lights up under any conditions as listed below:
a) Low-voltage protection(DC input voltage lower than Min. input voltage of inverters ).
b) Over-voltage protection (DC input voltage higher than Max. input voltage of
inverters).
c) Over-temperature protection (inverters will be shut down for power output when
the temperature of body of inverters higher than 65-75 °C .) And inverter will be
automatically restart up when the temperature of body of the inverter down to
40-50°C.
d) Power grid fault protection (when 110VAC or 220VAC grid power outage and/or
tripped.
e) Islanding protection: inverter will be automatically shut down for power output
when disconnect with power grid.
f) Short-circuit protection: inverter stops work when output line short-circuits.
1.2 Red LOW indicator: DC input voltage lower than 37VDC
1.3 Red High indicator: DC input voltage higher than 37VDC
1.4 Red Power LED indicator: Follow the inverter power output size flow flashing quickly
or slowly.
2. Blue ST LED
a) Blue LED flash: adjusting for power output, MPPT operating for tracking.
b) Blue LED long light: indicates inverter locking-in Max. output power operation status.
3. Green LED
a) 120VAC/230VAC indicators: associated LED lights up when run for power grid voltage
detection.
b) 50/60Hz indicators: associated LED lights up when run for frequency detection.
4. Please note that above operations only run at grid-connected status.
Warranty:
Warranty Conditions
Warranty Period: 15-year limited warranty period.
Warranty Time Start: From the date of bill of lading
Warranty Evidence: The B/L, Product(s) series number(s), Product(s) model, and a completed warranty card.
If your device has a defect or malfunction during the warranty period, please contact your retailer or installer.
Warranty claims are excluded for:
• Alterations or repairs to the unit without prior authorization
• Improper use or operation of device
• Improper and non-standard installation
• operating the equipment with defective safety devices
• Impact of foreign objects and force majeure (lightning, surge, storm, fire)
• Inadequate or nonexistent ventilation of the device
• disregarding of safety regulations
• shipping damage
• The Product has been improperly stored or was damaged while in possession of the Dealer or end user;
WARNING! Only qualified electrical professionals can do the trouble shooting of the Smart Microinverter system. WARNING! Please turn off the Smart Microinverter first and then disconnect
the AC grid before disconnecting the Smart Microinverter from the PV module when remove the inverter from the rack.
WARNING: Do not attempt to repair the Smart Microinverter. This may bring electrical hazard to the person and it will also void the Microinverter warranty. If troubleshooting methods fail, please
contact customer support to return the Microinverter and initiate for replacement process.
If the product has the following problems, we can assist you for repairing:
Problem NO. 1: Halted, No LED Indicating
Problem NO. 2: 230v or 110V LED, 50 Hz or 60 Hz LED, ST LED, and Low or High LED
Light; Power LED Runs Up and Down, But No Power Output.
Problem NO.3: FAULT LED Lights, LOW or HIGH LED Lights, But No Power Output
Problem No. 4: DC Fuses Open-Circuited
Problem No. 5: AC Fuses Open-Circuited